18926463275

热门搜索:

维尔克斯光电是多家欧美光电子、激光公司在中国区的代理商 维尔克斯光电经营的主要产品包括:衍射光学元件,DOE,整形镜,分束器,匀化器,微透镜阵列,离轴抛物面镜,螺旋相位板,各类太赫兹元件,科研激光器,LDX激光,光斑分析仪,激光准直仪,激光防护眼镜,滤光片,消色差波片,可饱和吸收镜,SESAM,

    Laser Meter

    更新时间:2024-04-17   浏览数:1291
    所属行业:仪器仪表 光学仪器
    发货地址:广东省深圳市龙岗区  
    产品数量:1.00台
    价格:¥20000.00 元/台 起
    product nameLaser Power Meter The laser power sensors cover the range from10W to 500W Brand Highlightoptics Wavelength range0.19-11μm Quick response 0 %-95% response time 1.5sec High damage threshold 11 kW/cm2@40 W Model TP10-HP-19,TP200-HP-25,Lynk-USB-10-HP-19,Lynk-RS232-5-HP-19,Lynk-USB-200-HP-25



    Laser power meter is an instrument used to test the power of a continuous laser or the average power of a pulsed laser. 
    Highlightoptics provides a series Laser Power Meter, such as 10W, 50W, 200W and 500W with air cool. With a compact design and a practical performance, the power meters are easy to use in laser producing and laser equipment area. The power detector have high power damage threshold. For example, the 50 W detector can used CW with 50 W, 150 W in 1.5 Min. It is easy integration and easy installation to equipment.
    The power meter display has high resolution color TFT Screen, Two-stage Backlight Square Port USB Interface. It could be used for charging, power supply and data upload. 

    Laser Power Meter Parameters
    Display (Mater):
    Model Stellar
    Display 2.8 Inch TFT, 400*240 pixel
    Mode Digital display, waveform, curve
    Detector TP Series
    Battery 200mA,Lithiwm ion rechargeable battery
    Memory 10000 max, Storage time: 1667 hour max
    Power 5V1A
    Interface USB/RS232
    Dimensions 170*96*28(mm)
    Material Metal
    Weight 500g
    Detector:
    Range 20mW—500W, Optional
    Resolution 0.001W—0.1W, Optional
    Response time 1.5 Sec(50W Laser)
    Threshold 18KW/cm2
    Accuracy ±1.0+1%
    Repeatability 1%
    Linearity 1%
    Error range ±2%,(NIST:±3%)
    Buyer’s guide:
    Model Rang Aperture Cooling Threshold Resolution
    TP10-HP-19 20mW—10W 19mm air cool 15KW/cm2 0.001W
    TP50-HP-19 20mW—50W 19mm air cool 15KW/cm2 0.01W
    TP200-HP-25 0.2W—200W 25mm air cool 7KW/cm2 0.01W
    TP500-HP-25 0.5W—500W 25mm air cool 5KW/cm2 0.1W
    TP50-HP-19-E 50mJ—200J 19mm air cool 15KW/cm2 0.001J
    TP200-HP-25-E 100mJ—300J 25mm air cool 7KW/cm2 0.001J
    Stellar The above probes need to be matched with the meters.
    *With E detector is an Energy meter, can only measure with 1HZ, single shot energy
    *50W detector measure 150W in 1.5Min,


    USB/RS232 Laser Power Meter
    Model Rang Apertur Cooling Threshold Resolution
    Lynk-USB-10-HP-19 20mW—10W 19mm Air cool 15KW/cm2 0.001W
    Lynk-USB-50-HP-19 20mW—50W 19mm Air cool 15KW/cm2 0.01W
    Lynk-USB-50-HP-19-B 20mW—50W 19mm Air cool 15KW/cm2 0.01W
    Lynk-USB-200-HP-25 0.2W—200W 25mm Air cool 7KW/cm2 0.01W
    Lynk-USB-500-HP-25 0.5W—500W 25mm Air cool 5KW/cm2 0.1W


    10W, 50W Laser power sensor Product features
    Detector:
    -Quick response (50 W detector : 0 %-95% response time 1.5sec)
    - High damage threshold: 11 kW/cm2@40 W 
    - Wavelength range: 0.19-11μm
    - NIST standard
    - Compact design
    - Connect to Meter


    Model TP10-HP-19 TP50-HP-19
    Max. Average Power 10 W 50 W
    Min. Power 20 mW 50 mW
    Power Resolution 0.001 W 0.01 W
    Noise Equivalent Power(NEP) 1 mW 20 mW
    Response Time 1 sec 1.5 sec
    Power Calibration Uncertainty ± 3% ± 3%
    Power Linearity(1) ± 1% ± 1.5%
    Aperture 19 mm 19mm
    Type HPB HPB
    Absorber Specs
    Absorber Spectral Range 0.19 - 11 μm 0.19 - 11 μm
    Calibration Spectral Range 0.19 - 2.1 μm, 2.94 μm,9 - 11μm 0.19 - 2.1 μm, 2.94 μm,9 - 11μm
    Max Power Density(2) 15kW/cm2@10W 11kW/cm2@40W
    General Characteristics
    Cooling Conduction(a) Conduction(a)
    Weight Dimension 1.0 kg 1.5 kg
    Dimension 65×65×35mm 65×65×45mm
    Cable length - connector 2.5 m 2.5m
    Notes (1). Detector centrally irradiated @50% of useful surface,
    (2). Damage thresholds also depend on power level. Please see damage graphs for more details.


    200W, 500W Laser power sensor Product features 
    Detector:
    - Quick response (500 W detector : 0 %-95% response time 3sec)
    - High damage threshold: 11 kW/cm2@40 W 
    - Wavelength range: 0.19-11μm
    - NIST standard
     


    Model TP200-HP-25 TP500-HP-25
    Max. Average Power 200 W 500 W
    Min. Power 0.2 W 0.5 W
    Power Resolution 0.1 W 0.1 W
    Noise Equivalent Power(NEP) 200 mW 500 mW
    Response Time 2 sec 5 sec
    Power Calibration Uncertainty ± 3% ± 3%
    Power Linearity(1) ± 1% ± 1.5%
    Aperture 25 mm 25mm
    Type HPB HPB
    Absorber Specs
    Absorber Spectral Range 0.19 – 25 μm 0.19 – 11 μm
    Calibration Spectral Range 0.19 – 2.1 μm, 2.94μm, 9 – 11 μm 0.19 – 2.1 μm,2.94μm, 9 – 11μm
    Max Power Density(2) 5kW/cm2@200W 3kW/cm2@500W
    General Characteristics
    Cooling Conduction(a) Conduction(a)
    Weight Dimension 1.5 kg 2.0 kg
    Dimension 90×90×70 mm 122×122×118mm
    Cable length - connector 2.5 m 2.5 m
    Notes (1). Detector centrally irradiated @50% of useful surface,
    (2). Damage thresholds also depend on power level. Please see damage graphs for more details.


    USB/RS232 Laser Power Meter Product features
    5W,10W,50W Detectors:
    - Quick response (50 W detector : 0 %-95% response time 1.5 sec)
    - High damage threshold: 11 kW/cm2@40 W 
    - Wavelength range: 0.19-11μm
    - NIST standard
    - Compact design
    - Connect to Meter
     


    Model Lynk-RS232-5-HP-19 Lynk-RS232-50-HP-25
    Max. Average Power 5 W 50 W
    Min. Power 10 mW 50 Mw
    Power Resolution 1 mW 10 mW
    Noise Equivalent Power(NEP) 500 μW 20 mW
    Response Time 0.7 sec 1.5 sec
    Power Calibration Uncertainty ± 3% ± 3%
    Power Linearity(1) ± 1% ± 1.5%
    Aperture 19 mm 25 mm
    Type HPB HPB
    Absorber Specs
    Absorber Spectral Range 0.19 – 11 μm 0.19 – 11 μm
    Calibration Spectral Range 0.19 – 2.1μm,2.94μm,9 – 11μm 0.19 – 2.1μm,2.94μm,9 – 11μm
    Max Power Density(2) 18 KW/cm2 11KW/cm2@40 W
    General Characteristics
    Cooling Conduction(a) Conduction(a)
    Weight Dimension 0.15 kg 0.20 kg
    Dimension 60×60×20 mm 60×60×20 mm
    Cable length - connector 2.5 m – USB/1.5m – RS232 2.5 m – USB/1.5m – RS232
    Notes (1). Detector centrally irradiated @50% of useful surface,
    (2). Damage thresholds also depend on power level. Please see damage graphs for more details.


    Model Lynk-USB-10-HP-19 Lynk-USB-50-HP-19
    Max. Average Power 10 W 50 W
    Min. Power 20m W 50 mw
    Power Resolution 1 mW 10 mW
    Noise Equivalent Power(NEP) 500 μW 20 mW
    Response Time 0.7 sec 1.5 sec
    Power Calibration Uncertainty ± 3% ± 3%
    Power Linearity(1) ± 1% ± 1.5%
    Aperture 19 mm 19 mm
    Type HPB HPB
    Absorber Specs
    Absorber Spectral Range 0.19 – 11 μm 0.19 – 11 μm
    Calibration Spectral Range 0.19 – 2.1μm,2.94μm,9 – 11μm 0.19 – 2.1μm,2.94μm,9 – 11μm
    Max Power Density(2) 18 KW/cm2@10W 11 KW/cm2@40 W
    General Characteristics
    Cooling Conduction(a) Conduction(a)
    Weight Dimension 0.15 kg 0.20 kg
    Dimension 60×60×45mm 60×60×45 mm
    Cable length - connector 2.5 m – USB/1.5m – RS232 2.5 m – USB/1.5m – RS232
    Notes (1). Detector centrally irradiated @50% of useful surface,
    (2). Damage thresholds also depend on power level. Please see damage graphs for more details.


    200W,500W Detectors:
    - Quick response(50 W detector : 0 %-95% response time 1.5 sec)
    - High damage threshold: 11 kW/cm2@40 W 
    - Wavelength range: 0.19-11μm
    - NIST standard
    - Compact design
    - Connect to Meter
     


    Model Lynk-USB-200-HP-25 Lynk-USB-500-HP-25
    Max. Average Power 200 W 500 W
    Min. Power 0.2 W 0.5 w
    Power Resolution 10 mW 100 mW
    Noise Equivalent Power(NEP) 2 mW 50 mW
    Response Time 2 sec 5 sec
    Power Calibration Uncertainty ± 3% ± 3%
    Power Linearity(1) ± 1% ± 1.5%
    Aperture 25 mm 25 mm
    Type HPB HPB
    Absorber Specs
    Absorber Spectral Range 0.19 – 11 μm 0.19 – 11 μm
    Calibration Spectral Range 0.19 – 2.1μm,2.94μm,9 – 11μm 0.19 – 2.1μm,2.94μm,9 – 11μm
    Max Power Density(2) 4 KW/cm2@200W 3 KW/cm2@500 W
    General Characteristics
    Cooling Conduction(a) Conduction(a)
    Weight Dimension 1.5 kg 2.0 kg
    Dimension 90×90×70mm 122×122×118 mm
    Cable length - connector 2.5 m – USB/1.5m – RS232 2.5 m – USB/1.5m – RS232
    Notes  (1). Detector centrally irradiated @50% of useful surface.
    (2). Damage thresholds also depend on power level. Please see damage graphs for more details.



    http://welloptics.cn.b2b168.com